 Current Transducer LB 500-S/SP1
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
500 A
Preliminary
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC Vd @ 500 A max @ 750 A max 500 0 .. 750 RM min RM max 5 5 200 1 : 2500 15 20 + IS 6 1) 33 15 A A mA V mA kV
Features
* Closed loop (compensated) current
transducer using the Hall effect
* Insulated plastic case recognized
according to UL 94-V0.
Special features
* VC = 15 ( 5 %) V * K N = 1 : 2500 * Low thermal offset drift with
temperature
Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Accuracy - Dynamic performance data
X
* Better zero crossing performance * TA = + 10C .. + 50C * Shield between primary and
secondary connected to VC " - "
L
Accuracy @ IPN, TA = 25C Linearity Offset current @ IP = 0, TA = 25C Thermal drift of IO + 10C .. + 50C Response time 2) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) Zero crossing distortion
0.5 < 0.1 Typ
% % Max 0.500 mA 0.064 mA s A/s kHz
Advantages
* * * * * * *
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability.
IO IOT tr di/dt f
<1 > 50 DC .. 150 negligeable
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 50C Mass Standards + 10 .. + 50 - 25 .. + 85 30 670 EN 50178 C C g
Applications
* AC variable speed drives and servo
motor drives
* Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies
(UPS)
* Switched Mode Power Supplies
(SMPS)
* Power supplies for welding
applications Notes :
1) 2)
Between primary and secondary. With a di/dt of 100 A/s
* HVDC transmisions.
990803/2
LEM Components
w w w .lem.com
Dimensions LB 500-S/SP1
Right view
(in mm. 1 mm = 0.0394 inch)
Front view
Secondary terminals
Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V
Connection
Top view Mechanical characteristics
* * * *
General tolerance Fastening Primary through-hole Connection of secondary Fastening torque 0.5 mm 4 slots 6.5 mm 25 mm M5 threaded studs 2.2 Nm or 1.62 Lb. - Ft.
Remarks
* IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed
70C.
* Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.


▲Up To Search▲   

 
Price & Availability of LB500-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X